quad-ilm

Singlemode / Multimode Insertion Loss Measurement Equipment 1310/1550nm & 850/1300nm

Sku:

Quick Overview

The ILM-422 is the ideal singlemode / multimode test combination.  A high stability quad singlemode/multimode source and multi-wavelength meter, USB download and spreadsheet software make loss test reporting easy and fast.

If you are tired of handwriting test reports then the ILM-422 package is what you need. The ILM-422 test set has built in data storage and you can easily download results to a PC and import them to a Loss Test Report that automatically calculates the loss of the cable and produces a Professional PDF in just 4 minutes saving 26 minutes per report. A bi-directional, 2 wavelength report done by hand takes 30 minutes.

In addition, the ILM-422 meter detects the wavelength of the source and matches to it so that wavelength errors are eliminated and a fibre link can be tested quickly and reliably without the need for constant communication between the operators. You can then avoid the errors made when the source is at one wavelength and the meter is set at another.

ILM-422 delivers the four key fibre test wavelengths 850/1300 multimode and 1310/1550nm singlemode.

 

Light Source

Wavelength850/1300nm Multimode

1310/1550nm Singlemode

Key wavelengths in modern transmission systems these can be detected by the meter which will automatically switch wavelength to match
Emitter TypeLaser DiodeMatches modern Transmitter types
Output StabilityShort Term (15 mins)

+/-0.1dB @850 & 1300nm

 < +/- 0.05dB @ 1310 & 1550nm

Long Term (8 hours)

+/-0.2dB @850 & 1300nm

 < +/- 0.1dB @ 1310 & 1550nm

Suitable for long short term and long term measurements
Central Wavelength850:  +/-10nm

1300,1310,1550:  +/-20nm

 
Spectral Width 5nm 
Output FrequencyCW, 270Hz, 1kHz, 2kHzCan be detected automatically by the meter
Output Power-5dBmDynamic range with power meter is 65dB (meter option A) and 45dB (meter option B—high power option)
Auto Power OffYesSaves power but can be  disabled
BacklightYes 
Operating Temperature-10 to +50 degrees Celsius 
Power SupplyRechargeable NiMH AA  supplied

AA Dry Cells may be used

 
Size and weight160 x 76 x 45mm   270 grams 

 

Power Meter

 Option AOption B
Calibrated Wavelengths850, 1300,1310,1490,1550, 1625nm
Power Range+10 to –70dBm+26 to –50dBm
Detector TypeInGaAs
Connector TypeInterchangeable FCPC and SCPC Supplied
Accuracy+/-5% +/- 1nW+/-5% +/- 10nW
Resolution0.01dB  @ -60dBm to +10dBm

0.1dB @ -70dBm to –60dBm

0.01dB  @ -40dBm to +26dBm

0.1dB @ -50dBm to –40dBm

Linearity+/-5%
Auto Power OffYes
BacklightYes
Reference value StorageYes
USB ConnectionYes
Data StorageYes
Wavelength RecognitionYes
Tone Detection270Hz, 1kHz, 2kHz
Operating Temperature-10 to +50 degrees Celsius
Power SupplyRechargeable NiMH AA  supplied

AA Dry Cells may be used

Size and weight160 x 76 x 45mm   270 grams
Standard AccessoriesFCPC and SCPC adapters supplied, rechargeable batteries, charger, USB cable, test report,  carrying pouch, CD software, user manual
Optional AccessoriesST Adapter, Male FC to Female LC adapter

 

Call Now Button