If you are tired of handwriting test reports then the ILM-422 package is what you need. The ILM-422 test set has built in data storage and you can easily download results to a PC and import them to a Loss Test Report that automatically calculates the loss of the cable and produces a Professional PDF in just 4 minutes saving 26 minutes per report. A bi-directional, 2 wavelength report done by hand takes 30 minutes.
In addition, the ILM-422 meter detects the wavelength of the source and matches to it so that wavelength errors are eliminated and a fibre link can be tested quickly and reliably without the need for constant communication between the operators. You can then avoid the errors made when the source is at one wavelength and the meter is set at another.
ILM-422 delivers the four key fibre test wavelengths 850/1300 multimode and 1310/1550nm singlemode.
Light Source
Wavelength | 850/1300nm Multimode
1310/1550nm Singlemode |
Key wavelengths in modern transmission systems these can be detected by the meter which will automatically switch wavelength to match |
Emitter Type | Laser Diode | Matches modern Transmitter types |
Output Stability | Short Term (15 mins)
+/-0.1dB @850 & 1300nm < +/- 0.05dB @ 1310 & 1550nm Long Term (8 hours) +/-0.2dB @850 & 1300nm < +/- 0.1dB @ 1310 & 1550nm |
Suitable for long short term and long term measurements |
Central Wavelength | 850: +/-10nm
1300,1310,1550: +/-20nm |
|
Spectral Width | 5nm | |
Output Frequency | CW, 270Hz, 1kHz, 2kHz | Can be detected automatically by the meter |
Output Power | -5dBm | Dynamic range with power meter is 65dB (meter option A) and 45dB (meter option B—high power option) |
Auto Power Off | Yes | Saves power but can be disabled |
Backlight | Yes | |
Operating Temperature | -10 to +50 degrees Celsius | |
Power Supply | Rechargeable NiMH AA supplied
AA Dry Cells may be used |
|
Size and weight | 160 x 76 x 45mm 270 grams |
Power Meter
Option A | Option B | |
Calibrated Wavelengths | 850, 1300,1310,1490,1550, 1625nm | |
Power Range | +10 to –70dBm | +26 to –50dBm |
Detector Type | InGaAs | |
Connector Type | Interchangeable FCPC and SCPC Supplied | |
Accuracy | +/-5% +/- 1nW | +/-5% +/- 10nW |
Resolution | 0.01dB @ -60dBm to +10dBm
0.1dB @ -70dBm to –60dBm |
0.01dB @ -40dBm to +26dBm
0.1dB @ -50dBm to –40dBm |
Linearity | +/-5% | |
Auto Power Off | Yes | |
Backlight | Yes | |
Reference value Storage | Yes | |
USB Connection | Yes | |
Data Storage | Yes | |
Wavelength Recognition | Yes | |
Tone Detection | 270Hz, 1kHz, 2kHz | |
Operating Temperature | -10 to +50 degrees Celsius | |
Power Supply | Rechargeable NiMH AA supplied
AA Dry Cells may be used |
|
Size and weight | 160 x 76 x 45mm 270 grams | |
Standard Accessories | FCPC and SCPC adapters supplied, rechargeable batteries, charger, USB cable, test report, carrying pouch, CD software, user manual | |
Optional Accessories | ST Adapter, Male FC to Female LC adapter |